Home › Free calculators › Tube-side heat transfer coefficient
Free calculator

Tube-side heat transfer coefficient

Film coefficient inside tubes by Gnielinski, Dittus–Boelter and Sieder–Tate — velocity, Reynolds and Prandtl numbers, with water properties built in.

Inputs

Units:
Tube-side fluid
cP
cP
Tubes

Results

Using this for a real decision? The Shell and Tube Heat Exchanger Performance and Fouling Excel tool checks every input, works in your units and prints a report for your files. USD 49 →

Need the full version for your plant?

The Shell and Tube Heat Exchanger Performance and Fouling Excel tool does everything here and more: actual U, fouling resistance and cleanliness from plant readings — with the duty lost to fouling, its yearly cost and the best cleaning interval. Print-ready report, any units, visible formulas, no macros.

Join PlantCalcKit — free

Be first to hear about new calculators, Excel tools and field guides — one short email when something new is ready. The calculators stay free with or without an account.

By joining you agree to our privacy policy. Unsubscribe or delete your details any time.

How this calculator works

The film coefficient h on the inside of a tube is the first resistance in any heat exchanger's overall U. This calculator works out the velocity in each tube, the Reynolds and Prandtl numbers and h by the correlation that fits the flow: Gnielinski (with the Petukhov friction factor) for turbulent and transitional flow — the most accurate of the common correlations, typically within about 10 % — and Sieder–Tate for developing laminar flow. Dittus–Boelter and turbulent Sieder–Tate are shown alongside, because many data sheets and older calculations use them. Water properties — density, heat capacity, viscosity and conductivity — come from the IAPWS formulations; for other fluids enter them.

Example: 100,000 kg/h of cooling water at 30 °C through 120 tubes per pass of 15.75 mm inside diameter (¾-inch, 16 BWG), 6.1 m long: 1.19 m/s, Re = 23,470, Pr = 5.42, and a film coefficient of 6,006 W/m²·K by Gnielinski (Dittus–Boelter 5,534, Sieder–Tate 5,804); the tube friction is 0.07 bar per pass. The correlations were checked against the open-source ht library at a range of Reynolds and Prandtl numbers (agreement to 0.0001 %), and the water properties against the iapws library (within 0.3 %).

Limits: single-phase flow in round, smooth tubes; between Re = 2,300 and 10,000 any correlation is uncertain. For liquids give a wall temperature (or wall viscosity) to apply the viscosity correction — it matters for oils. Add the shell-side coefficient, the wall and the fouling resistances for U; the LMTD calculator works out the area. References: V. Gnielinski, Int. Chem. Eng. 16 (1976) 359; Sieder and Tate, Ind. Eng. Chem. 28 (1936) 1429; Dittus and Boelter (1930); Incropera and DeWitt, Fundamentals of Heat and Mass Transfer, ch. 8; IAPWS-IF97, IAPWS 2008 and 2011.